root@pcdbhmx1 # fmadm faulty -ai
root@pcdbhmx1 # fmdump -v

root@#fmadm repair f9b64deb-c196-e117-bbe0-d3c2bde09269

TIME                 UUID                                 SUNW-MSG-ID
May 27 2011 11:32:49 14a44eac-a312-e70d-8002-c513c146a646 PCIEX-8000-3S
   29%  fault.io.pciex.device-interr

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=1
           Affects: dev:////pci@16,600000/network@0,1
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

   29%  fault.io.pciex.device-interr

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=0
           Affects: dev:////pci@16,600000/network@0
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

   14%  fault.io.pciex.device-interr

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0
           Affects: dev:////pci@16,600000
               FRU: hc:///component=iou#3-pci#6
          Location: -

   14%  fault.io.pciex.bus-linkerr

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=1
           Affects: dev:////pci@16,600000/network@0,1
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

   14%  fault.io.pciex.bus-linkerr

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=0
           Affects: dev:////pci@16,600000/network@0
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

Jun 15 18:11:04.8734 14a44eac-a312-e70d-8002-c513c146a646 FMD-8000-4M Repaired
   29%  fault.io.pciex.device-interr    Repair Attempted

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=1
           Affects: dev:////pci@16,600000/network@0,1
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

   29%  fault.io.pciex.device-interr    Repair Attempted

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=0
           Affects: dev:////pci@16,600000/network@0
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

   14%  fault.io.pciex.device-interr    Repair Attempted

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0
           Affects: dev:////pci@16,600000
               FRU: hc:///component=iou#3-pci#6
          Location: -

   14%  fault.io.pciex.bus-linkerr      Repair Attempted

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=1
           Affects: dev:////pci@16,600000/network@0,1
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

   14%  fault.io.pciex.bus-linkerr      Repair Attempted

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=0
           Affects: dev:////pci@16,600000/network@0
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

Jun 15 18:11:04.8987 14a44eac-a312-e70d-8002-c513c146a646 FMD-8000-6U Resolved
   29%  fault.io.pciex.device-interr    Repair Attempted

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=1
           Affects: dev:////pci@16,600000/network@0,1
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

   29%  fault.io.pciex.device-interr    Repair Attempted

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=0
           Affects: dev:////pci@16,600000/network@0
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

   14%  fault.io.pciex.device-interr    Repair Attempted

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0
           Affects: dev:////pci@16,600000
               FRU: hc:///component=iou#3-pci#6
          Location: -

   14%  fault.io.pciex.bus-linkerr      Repair Attempted

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=1
           Affects: dev:////pci@16,600000/network@0,1
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

   14%  fault.io.pciex.bus-linkerr      Repair Attempted

        Problem in: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0/pciexfn=0
           Affects: dev:////pci@16,600000/network@0
               FRU: hc://:product-id=SUNW,SPARC-Enterprise:chassis-id=AKD1102103:server-id=pcdbhmx1/chassis=0/ioboard=3/hostbridge=3/pciexrc=0/pciexbus=2/pcxdev=0
          Location: iou#3-pci#6

root@pcdbhmx1 # cd /var/fm/fmd
root@pcdbhmx1 # rm e* f* c*/eft/* r*/*
c*eft/*: No such file or directory
r*/*: No such file or directory
root@pcdbhmx1 # svcs -a | grep fmd
online         18:06:43 svc:/system/fmd:default
root@pcdbhmx1 # svcadm disable fmd
root@pcdbhmx1 # svcs -a | grep fmd
disabled       18:13:11 svc:/system/fmd:default
root@pcdbhmx1 # svcadm enable fmd
root@pcdbhmx1 # fmdump -v
TIME                 UUID                                 SUNW-MSG-ID
fmdump: /var/fm/fmd/fltlog is empty
root@pcdbhmx1 # fmadm faulty -ai
root@pcdbhmx1 #