Wednesday, February 6, 2013

In case communication with XSCF is lost

In case communication with XSCF is lost)
11-10
SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
of the maintenance menu returns to the initial page, the operation is
completed.
During execution of the maintenance command (such as the replacefru
command) in the active XSCF unit, in case communication with XSCF is lost
for some reason such as LAN disconnection, re-execute the command in the
manner described below:
i. Reconnect to XSCF.
In case multiple maintenance commands executed, the XSCF becomes
locked status and the message as follows appears.
Unable to perform maintenance commands at this time.
Another user is currently executing a maintenance command.
When the above message displayed, execute the unlockmaintenance
command to forcibly release the XSCF locked status

No comments: